1.
Anal Chem ; 90(20): 12011-12018, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30220198

RESUMO

We evaluate the performance of a new chemical ionization source called Vocus, consisting of a discharge reagent-ion source and focusing ion-molecule reactor (FIMR) for use in proton-transfer-reaction time-of-flight mass spectrometry (PTR-TOF) measurements of volatile organic compounds (VOCs) in air. The reagent ion source uses a low-pressure discharge. The FIMR consists of a glass tube with a resistive coating, mounted inside a radio frequency (RF) quadrupole. The axial electric field is used to enhance ion collision energies and limit cluster ion formation. The RF field focuses ions to the central axis of the reactor and improves the detection efficiency of product ions. Ion trajectory calculations demonstrate the mass-dependent focusing of ions and enhancement of the ion collision energy by the RF field, in particular for the lighter ions. Product ion signals are increased by a factor of 10 when the RF field is applied (5000-18 000 cps ppbv-1), improving measurement precision and detection limits while operating at very similar reaction conditions as traditional PTR instruments. Because of the high water mixing ratio in the FIMR, we observe no dependence of the sensitivity on ambient sample humidity. In this work, the Vocus is interfaced to a TOF mass analyzer with a mass resolving power up to 12 000, which allows clear separation of isobaric ions, observed at nearly every nominal mass when measuring ambient air. Measurement response times are determined for a range of ketones with saturation vapor concentrations down to 5 × 104 µg m-3 and compare favorably with previously published results for a PTR-MS instrument.

2.
Anal Chem ; 82(22): 9336-43, 2010 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-20964441

RESUMO

The design of a new ion mobility mass spectrometer (IM-MS) is presented. This new design features an ambient-pressure resistive glass ion mobility drift tube (RGIMS) coupled to a high-resolution time-of-flight mass spectrometer (TOFMS) by an enhanced interface that includes two segmented quadrupoles. The interface design demonstrates an increase in sensitivity while maintaining high resolving power typically achieved for ambient-pressure IMS drift tubes. Performance of the prototype instrument was evaluated and the analytical figures of merit for standard solutions as well as complex samples such as human blood were determined. For a 3 µM solution of caffeine, the peak was collected in 36 s and gave a response of 10 counts/s. The detection limit (defined as 1 count/s) was calculated to be 300 nM concentration of caffeine from the response rate from the 36 s run. Controlled fragmentation of caffeine was achieved through adjustment of voltages applied on the interface lenses. Over 300 tentative metabolites were detected in human blood along with 80 isomers/isobars with ion counts >5. Isotope ratios from extracted mass spectra of selected mobility peaks were used to identify selected metabolite compounds. High separation power for both IMS (resolving power, t(d)/Δt(w1/2), was 85) and MS (mass resolving power, m/Δm, maximum was 7000 with a mass accuracy between 2 and 10 ppm) was measured. Developed software for data acquisition, control and display allowed flexibility in instrument control, data evaluation and visualization.


Assuntos
Vidro , Espectrometria de Massas/instrumentação , Análise Química do Sangue , Cafeína/química , Desenho de Equipamento , Humanos , Limite de Detecção , Metaboloma , Pressão , Fatores de Tempo
3.
J Ocul Pharmacol Ther ; 26(6): 597-603, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20977366

RESUMO

PURPOSE: To evaluate the efficacy and tolerability of preservative-free eye drops (dorzolamide/timolol) in routine management of preservative-sensitive glaucoma patients. METHODS: Data from 2,298 glaucoma patients requiring intraocular pressure (IOP) reduction and suffering from intolerance to benzalkonium chloride or active agents of previously used eye drops were valid for baseline and safety analysis in this prospective, open, noncomparative, multicenter, noninterventional study. Patients were treated with preservative-free dorzolamide/timolol eye drops for 12 weeks. Main efficacy endpoint was IOP reduction after 12 weeks of treatment. Two thousand forty-nine patients were considered for efficacy analysis. Tolerability was assessed by evaluating adverse drug reactions. RESULTS: Mean baseline IOP was 20.8 mmHg. Baseline IOP was reduced to 16.7 mmHg after 12 weeks of treatment corresponding to a mean absolute (percent) change of -4.1 mmHg (-17.3%). The proportion of patients with IOP ≤21 mmHg increased from 59.9% at baseline to 94.6% after 12 weeks. The most frequently reported ocular adverse drug reactions were burning eyes (2.4%) and hyperemia (0.9%). Local tolerability improved in 79.3% of patients compared to their previous glaucoma therapy. CONCLUSIONS: This observational study confirms the IOP lowering effect of preservative-free eye drops containing the fixed combination of dorzolamide/timolol in a large patient's population. The drug was well tolerated and improved the local tolerability in the vast majority of patients.


Assuntos
Anti-Hipertensivos/uso terapêutico , Glaucoma de Ângulo Aberto/tratamento farmacológico , Pressão Intraocular/efeitos dos fármacos , Sulfonamidas/uso terapêutico , Tiofenos/uso terapêutico , Timolol/uso terapêutico , Administração Tópica , Idoso , Anti-Hipertensivos/administração & dosagem , Anti-Hipertensivos/efeitos adversos , Compostos de Benzalcônio/efeitos adversos , Combinação de Medicamentos , Feminino , Humanos , Hiperemia/induzido quimicamente , Masculino , Soluções Oftálmicas , Conservantes Farmacêuticos/efeitos adversos , Estudos Prospectivos , Sulfonamidas/administração & dosagem , Sulfonamidas/efeitos adversos , Tiofenos/administração & dosagem , Tiofenos/efeitos adversos , Timolol/administração & dosagem , Timolol/efeitos adversos , Resultado do Tratamento
4.
Anal Bioanal Chem ; 398(3): 1435-45, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20669008

RESUMO

One- and comprehensive two-dimensional gas chromatography were hyphenated with soft photoionization mass spectrometry. The characteristics of these two- and three-dimensional comprehensive separation techniques are discussed in detail. Using the innovative electron beam pumped excimer light source (EBEL) for single-photon ionization (SPI), organic molecules with ionization energies (E ( i )) of below 9.8 eV can be detected by a time-of-flight mass spectrometer (TOF-MS). SPI with 126 nm vacuum ultraviolet (VUV) photons enables the universal and soft ionization of organic molecules. SPI-TOF-MS hyphenated to one-dimensional gas chromatography results in a comprehensive two-dimensional separation method (GCxMS). To demonstrate this, diesel fuel was analyzed, and the resulting GCxMS chromatograms are discussed in depth. A three-dimensional separation method was also realized by combining comprehensive two-dimensional gas chromatography (GCxGC) with SPI-MS. In the resulting separation space, constituents originating from mineral oil diesel blended with biodiesel were dispersed along the two GC separation axes, while the molecular mass axis served as a third separation dimension.

5.
J Am Soc Mass Spectrom ; 20(8): 1549-61, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19493684

RESUMO

This instrument combines the capabilities of ion/ion reactions with ion mobility (IM) and time-of-flight (TOF) measurements for conformation studies and top-down analysis of large biomolecules. Ubiquitin ions from either of two electrospray ionization (ESI) sources are stored in a three dimensional (3D) ion trap (IT) and reacted with negative ions from atmospheric sampling glow discharge ionization (ASGDI). The proton transfer reaction products are then separated by IM and analyzed via a TOF mass analyzer. In this way, ubiquitin +7 ions are converted to lower charge states down to +1; the ions in lower charge states tend to be in compact conformations with cross sections down to approximately 880 A(2). The duration and magnitude of the ion ejection pulse on the IT exit and the entrance voltage on the IM drift tube can affect the measured distribution of conformers for ubiquitin +7 and +6. Alternatively, protein ions are fragmented by collision-induced dissociation (CID) in the IT, followed by ion/ion reactions to reduce the charge states of the CID product ions, thus simplifying assignment of charge states and fragments using the mobility-resolved tandem mass spectrum. Instrument characteristics and the use of a new ion trap controller and software modifications to control the entire instrument are described.


Assuntos
Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Íons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Anal Chem ; 81(5): 1792-800, 2009 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-19175329

RESUMO

Vertical and horizontal profiles of atmospheric aerosols are necessary for understanding the impact of air pollution on regional and global climate. To gain further insight into the size-resolved chemistry of individual atmospheric particles, a smaller aerosol time-of-flight mass spectrometer (ATOFMS) with increased data acquisition capabilities was developed for aircraft-based studies. Compared to previous ATOFMS systems, the new instrument has a faster data acquisition rate with improved ion transmission and mass resolution, as well as reduced physical size and power consumption, all required advances for use in aircraft studies. In addition, real-time source apportionment software allows the immediate identification and classification of individual particles to guide sampling decisions while in the field. The aircraft (A)-ATOFMS was field-tested on the ground during the Study of Organic Aerosols in Riverside, CA (SOAR) and aboard an aircraft during the Ice in Clouds Experiment-Layer Clouds (ICE-L). Initial results from ICE-L represent the first reported aircraft-based single-particle dual-polarity mass spectrometry measurements and provide an increased understanding of particle mixing state as a function of altitude. Improved ion transmission allows for the first single-particle detection of species out to approximately m/z 2000, an important mass range for the detection of biological aerosols and oligomeric species. In addition, high time resolution measurements of single-particle mixing state are demonstrated and shown to be important for airborne studies where particle concentrations and chemistry vary rapidly.

7.
Anal Chem ; 79(20): 7782-91, 2007 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-17854161

RESUMO

In this article, we describe and characterize a novel ion mobility spectrometer constructed with monolithic resistive glass desolvation and drift regions. This instrument is equipped with switchable corona discharge and nanoelectrospray ionization sources and a Faraday plate detector. Following description of the instrument, pulsing electronics, and data acquisition system, we examine the effects of drift gas flow rate and temperature, and of the aperture grid to anode distance on the observed resolving power and sensitivity. Once optimum experimental parameters are identified, different ion gate pulse lengths, and their effect on the temporal spread of the ion packet were investigated. Resolving power ranged from an average value of 50 ms/ms for a 400-micros ion gate pulse, up to an average value of 68 ms/ms for a 100-micros ion gate pulse, and a 26-cm drift tube operated at 383 V cm(-1). Following these experiments, the radial distribution of ions in the drift region of the spectrometer was studied by using anodes of varying sizes, showing that the highest ionic density was located at the center of the drift tube. Finally, we demonstrate the applicability of this instrument to the study of small molecules of environmental relevance by analyzing a commercially available siderophore, deferoxamine mesylate, in both the free ligand and Fe-bound forms. Ion mobility experiments showed a dramatic shift to shorter drift times caused by conformational changes upon metal binding, in agreement with previous reversed-phase liquid chromatography observations.

8.
Anal Chem ; 78(24): 8281-9, 2006 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-17165817

RESUMO

The development of a new high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is reported. The high-resolution capabilities of this instrument allow the direct separation of most ions from inorganic and organic species at the same nominal m/z, the quantification of several types of organic fragments (CxHy, CxHyOz, CxHyNp, CxHyOzNp), and the direct identification of organic nitrogen and organosulfur content. This real-time instrument is field-deployable, and its high time resolution (0.5 Hz has been demonstrated) makes it well-suited for studies in which time resolution is critical, such as aircraft studies. The instrument has two ion optical modes: a single-reflection configuration offers higher sensitivity and lower resolving power (up to approximately 2100 at m/z 200), and a two-reflectron configuration yields higher resolving power (up to approximately 4300 at m/z 200) with lower sensitivity. The instrument also allows the determination of the size distributions of all ions. One-minute detection limits for submicrometer aerosol are <0.04 microg m(-3) for all species in the high-sensitivity mode and <0.4 microg m(-3) in the high-resolution mode. Examples of ambient aerosol data are presented from the SOAR-1 study in Riverside, CA, in which the spectra of ambient organic species are dominated by CxHy and CxHyOz fragments, and different organic and inorganic fragments at the same nominal m/z show different size distributions. Data are also presented from the MIRAGE C-130 aircraft study near Mexico City, showing high correlation with independent measurements of surrogate aerosol mass concentration.

9.
Anal Bioanal Chem ; 386(1): 169-79, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16773303

RESUMO

The figures of merit of a pulsed glow discharge time-of-flight mass spectrometer (GD-TOFMS) as a detector for gas chromatography (GC) analysis were evaluated. The mass resolution for the GD-TOFMS was determined on FWHM in the high mass range (208Pb+) as high as 5,500. Precision of 400 subsequent analyses was calculated on 63Cu+ to be better than 1% RSD with no significant drift over the time of the analysis. Isotope precision based on the 63Cu+/65Cu+ ratio over 400 analyses was 1.5% RSD. The limits of detection for gaseous analytes (toluene in methanol as solvent) were determined to be as low as several hundred ppb or several hundred pg absolute without using any pre-concentration technique. Furthermore, the different GD source parameters like capillary distance, cathode-anode spacing, and GD source pressure with regards to the accessible elemental, structural, and molecular information were evaluated. It was demonstrated that each of these parameters has severe influence on the ratio of elemental, structural, and parent molecular information in chemical speciation analysis.

10.
World J Surg ; 29(4): 422-8, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15770378

RESUMO

Despite curative tumor resection, about 30%-50% of patients with locally advanced gastrointestinal (GI) carcinoma develop tumor recurrence which may be caused by pre- or intraoperative tumor cell dissemination. We examined the combination of optimized density gradient centrifugation with a CK-20 reverse transcriptase-polymerase chain reaction to detect and quantify circulating tumor cells in peripheral blood. Peripheral venous blood (20 ml) of patients with GI carcinomas was collected during primary tumor staging before and after the endoscopy procedure. CK-20 expression in peripheral venous blood was found in 22 of 82 patients (26.8%) with a nonsignificant difference between the upper GI tract (23.9%) and the lower GI tract (30.5%). The correlation with clinical outcome (24-month-survival) revealed a significantly worse prognosis (p < 0.05) of CK-20-positive patients with carcinoma of the upper GI tract and a trend toward a worse prognosis for patients with carcinoma of the lower GI tract. Quantification of CK-20 expression in peripheral blood showed a significantly higher circulating CK-20 copy number (median: 2816) in patients with metastatic tumors than in those with non-metastatic tumors (median: 983) (p < 0.05). For a subset of 42 primarily operated patients, we correlated the detection rate with UICC (International Union Against Cancer) staging categories. In contrast to the upper GI tract, the detection rate of patients with carcinoma of the lower GI tract showed a trend toward tumor size (pT) and a significant correlation with the presence of distant metastases (pM) (p < 0.01) and the postoperative residual tumor status (R) (p < 0.01). The endoscopy procedure did not lead to an increased detection of CK-20 expression.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias Gastrointestinais/sangue , Proteínas de Filamentos Intermediários/metabolismo , Células Neoplásicas Circulantes/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Centrifugação com Gradiente de Concentração , Humanos , Queratina-20 , Masculino , Pessoa de Meia-Idade , Prognóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade
11.
Anal Chem ; 76(8): 2187-95, 2004 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15080727

RESUMO

Matrix-assisted laser desorption/ionization when combined with ion mobility-orthogonal time-of-flight mass spectrometry is a viable technique for fast separation and analysis of biomolecules in complex mixtures. Isobaric lipid, peptide, and oligonucleotide ions are preseparated before mass analysis by differences of up to 30% in mobility drift time. Ions of similar chemical type fall along well-defined "trend lines" (with deviations of approximately 3%) when plotted in two-dimensional representations of ion mobility as a function of m/z. Discussion of fundamental and technical limitations of the technique point to its potential for being most useful when applied to systems such as bodily fluids and intact tissue, where an alternative chemical or chromatographic preseparation step prior to mass analysis is either impractical or undesirable.


Assuntos
Lipídeos/química , Nucleotídeos/química , Peptídeos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Analgésicos Opioides/análise , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Morfina/análise , Saliva/química , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação
12.
Anal Chem ; 75(13): 3001-9, 2003 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-12964744

RESUMO

A prototype electron monochromator (EM) reflectron time-of-flight (TOF) mass spectrometer has been constructed and demonstrated to record resonant electron capture (REC) mass spectra of electron-capturing compounds. The electron energy is ramped from -1.7 to +25 eV at a preset frequency, and the energy spread of the electron beam at 15 nA is 100 meV or better. Ions are orthogonally extracted into the analyzer at a frequency of up to 80 kHz while maintaining an upper m/z-limit of at least 300 and a mass resolving power of approximately 1000. A complete REC mass spectrum, which includes an effective yield versus electron energy curve for each negative ion formed from the compound being analyzed, typically takes several days to produce with a quadrupole or magnetic sector mass spectrometer. With the EM TOF described in this work, three-dimensional negative ion electron capture spectra are recorded in an interval on the order of only 1 s and displayed in real time. This new analytical capability could make it possible to perform GC REC mass spectrometry as well as easier (a) to measure the temperature dependence of REC cross sections, (b) to determine enthalpies of negative ion formation (accurate determination of the enthalpy of ion formation requires knowledge of the translational energy released during a dissociative capture event), and (c) to provide complete thermochemical descriptions of dissociative electron attachment by measuring ion lifetimes.


Assuntos
Elétrons , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Ânions , Fluorocarbonos/análise , Fluorocarbonos/química , Metano/análogos & derivados , Metano/análise , Nitrobenzenos/análise , Nitrobenzenos/química
13.
J Biomol Tech ; 14(1): 1-8, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12901606

RESUMO

Matrix-assisted laser desorption ionization-ion mobility-orthogonal time-of-flight mass spectrometry (MALDI-IM oTOF MS) is a new technique that allows laser desorbed ion to be preseparated on the basis of their shape prior to mas analysis. Using this instrument, we tested the postulate that addition of a quaternary ammonium compound such as acetylcholine to the model phosphorylated peptide angio tensin II would enhance its detection by MALDI in two ways. First of all, the acetylcholine-peptide complex could ionize more efficiently than the bare phosphopeptide. Furthermore the ion mobility could separate the complex ion on the basis of its charge/volume from isobaric interferences, which would otherwise limit detection sensitivity.


Assuntos
Acetilcolina/química , Angiotensina II/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Timina/análogos & derivados , Substâncias Macromoleculares , Fosforilação , Timina/química , Triazinas
14.
Anal Bioanal Chem ; 373(7): 612-7, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12185573

RESUMO

Matrix-assisted laser-desorption ionization followed by ion-mobility separation and time-of-flight mass analysis (MALDI-IM-TOFMS) has been used to characterize native and chemically modified DNA oligonucleotides up to eight bases in length. Mobility resolution between 20 and 30 can be used to separate oligonucleotides of different length, but not to differentiate between isomers or even different compositions of the same length. MALDI-IM-TOFMS does, however, have additional utility in the analysis of mixtures of DNA oligonucleotides and peptides, because these classes of molecules can be distinguished on the basis of differences in their mobility. Oligonucleotide sequencing is also possible by MALDI-IM-TOFMS. Ion signals corresponding to nucleobase losses, w-type, and y-type fragments were identified by use of differences in ion mobility. MALDI-IM-TOFMS was also used to resolve DNA-platinum adducts from the corresponding unmodified oligonucleotides.


Assuntos
Oligodesoxirribonucleotídeos/análise , Oligodesoxirribonucleotídeos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Íons , Peso Molecular , Sequências Repetitivas de Ácido Nucleico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise de Sequência de DNA/métodos
15.
J Am Soc Mass Spectrom ; 13(2): 166-9, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11838019

RESUMO

Matrix-assisted laser desorption ionization ion mobility coupled to orthogonal time-of-flight mass spectrometry (MALDI-IM-oTOF MS) is evaluated as a tool for studying non-covalent complex (NCX) formation between peptides. The NCX formed between dynorphin 1-7 and Mini Gastrin I is used as a model system for comparison to previous MALDI experiments (Woods, A. S.; Huestis, M. A. J. Am. Soc. Mass Spectrom. 2001, 12, 88-96). The dynorphin 1-7/Mini Gastrin I complex is stable after more than a ms drift time through the He filled mobility cell. Furthermore, the effects of solution pH on NCX ion signal intensity is measured both by MALDI-IM-MS analysis and by nanoelectrospray mass spectrometry. When compared to the previous MALDI study this work shows that all three techniques give similar results. In addition, fragmentation can be observed from of the non-covalent complex parent ion that occurs prior to TOF mass analysis but after mobility separation, thus providing NCX composition information.


Assuntos
Peptídeos/química , Proteínas Quinases Dependentes de GMP Cíclico/metabolismo , Dinorfinas/química , Gastrinas/química , Concentração de Íons de Hidrogênio , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
SELEÇÃO DE REFERÊNCIAS